ATOZ TECHNOLOGIES & SERVICES
All Types of Home Appliances Repair & Services Contact:8099996622
Monday, November 6, 2017
Saturday, November 4, 2017
Types of problem in the split air conditioner
Air conditioner is working but not cooling
Air conditioner is working but low cooling
Air conditioner leaking water
Split ac indoor unit making noise
Air conditioner won't turn on
Air conditioner stabilizer output not coming
Air conditioner is working but low cooling
Air conditioner leaking water
Split ac indoor unit making noise
Air conditioner won't turn on
Air conditioner stabilizer output not coming
Thursday, June 23, 2016
lg refrigerator error codes
Error Code | Condition | Check/Repair | Shop Parts |
---|---|---|---|
Er FS | Freezer sensor error | Sensor and wiring connector problems | Thermistor (temperature sensor), Wiring harness, main Power control board (PCB) |
Er rS | Refrigerator sensor error | Sensor and wiring and connectors | Thermistor (temperature sensor), Wiring harness, Main power control board (PCB) |
F dS | Freezer defrost sensor | Sensor short or wiring problem | Controller assembly, which is a component that has the defrost thermistor (temperature sensor) and the fuse for the defrost system |
r dS | Refrigerator defrost sensor | Sensor short or wiring problem | Controller assembly, which is a component that has the defrost thermistor (temperature sensor) and the fuse for the defrost system |
Er HS | Humidity sensor | Sensor short or wiring problem | Humidity sensor |
Er IS | Ice maker sensor | Sensor short or wiring problem | Ice maker assembly; the sensor isn't usually sold separately. |
Er SS | Pantry sensor | The pantry is the deli drawer. Short in sensor or wiring problem. | Pantry temperature sensor |
Er rt | Room temperature sensor | Short in sensor or wiring problem | Room temperature sensor |
Er It | System error inside ice maker | Self-test ice maker routine | ice maker assembly |
Er gF | Flow meter error code | Water pressure, flow of water | Flow meter |
F dH | Sensor did not get over 40 F in defrost | Faulty fuse, heater, control board | Controller assembly, defrost heater, relay on control board |
r dH | Sensor did not get over 40 F | Faulty fuse, heater, control board | Controller assembly, defrost heater, relay on control board |
Er IF | The fan for the ice compartment failed | Icing fan blocked, ice fan motor is defective, wiring in the circuit is defective, or the control board has failed | Ice fan motor, Wiring harness, Power control board (PCB) |
Er FF | Evaporator fan failed | Fan motor, control board, wiring harness | Evaporator fan motor, Power control board, Wiring harness |
Er CF | Condenser fan motor is defective | Condenser fan motor, wiring or the control board | Condenser fan motor, Power control board, Wiring harness |
Er CO | Communication errorbb | Communication error between main board and display board | Display control board, Power control board, Wiring harness |
samsung refrigerator check list
Display LED = R-1
Location = a
Fresh Food Fan High speed
Location = a
Fresh Food Fan High speed
Display LED = R-1
Location = b
Fresh Food Fan Low speed
Location = b
Fresh Food Fan Low speed
Display LED = R-1
Location = c
Fresh Food Defrost Heater
Location = c
Fresh Food Defrost Heater
Display LED = R-1
Location = d
When 1st plugged in
Location = d
When 1st plugged in
Display LED = R-1
Location = e
High Temp Condition Ambient Over 93F degrees
Location = e
High Temp Condition Ambient Over 93F degrees
Display LED = R-1
Location = f
Low Temp condition Ambient Under 72F degrees
Location = f
Low Temp condition Ambient Under 72F degrees
Display LED = R-1
Location = e – f
Normal condition Ambient ( Between 73F – 91F)
Location = e – f
Normal condition Ambient ( Between 73F – 91F)
Display LED = R-1
Location = g
Demo Mode
Location = g
Demo Mode
Display LED = F-1
Location = a
Compressor On
Location = a
Compressor On
Display LED = F-1
Location = b
Freezer Fan on high
Location = b
Freezer Fan on high
Display LED = F-1
Location = c
Freezer Fan on low
Location = c
Freezer Fan on low
Display LED = F-1
Location = d
Freezer Defrost Heater on
Location = d
Freezer Defrost Heater on
Display LED = F-1
Location = e
Compressor Fan on high
Location = e
Compressor Fan on high
Display LED = F-1
Location = f
Compressor Fan on Low
Location = f
Compressor Fan on Low
Display LED = F-1
Location = g
When the Sparkling water to dispenser valve operates
Location = g
When the Sparkling water to dispenser valve operates
Display LED = R-10
Location = a
Damper Open
Location = a
Damper Open
Display LED = R-10
Location = c
Ice Maker heater operates
Location = c
Ice Maker heater operates
Display LED = R-10
Location = d
Full Ice
Location = d
Full Ice
Display LED = R-10
Location = e
(Sensor detects) Sparkling Water tank full
Location = e
(Sensor detects) Sparkling Water tank full
Display LED = R-10
Location = f
(Sensor detects) Sparkling Water tank low
Location = f
(Sensor detects) Sparkling Water tank low
Display LED = R-10
Location = e – f
(Sensor detects) Sparkling water tank empty
Location = e – f
(Sensor detects) Sparkling water tank empty
Display LED = F-10
Location = c
Sparkling Water Dispenser valve operates
Location = c
Sparkling Water Dispenser valve operates
Display LED = F-10
Location = d
Ice Room Fan – High Speed
Location = d
Ice Room Fan – High Speed
Display LED = F-10
Location = e
Ice Room Fan – Low Speed
Location = e
Ice Room Fan – Low Speed
Display LED = F-10
Location = f
Water to Dispenser valve operates – Sparkling only
Location = f
Water to Dispenser valve operates – Sparkling only
Display LED = F-10
Location = g
French Heater Operates
Location = g
French Heater Operates
Samsung Blinking Dash Line Error Code List
1 – Ice Maker Sensor – Ice Maker sensor connector missing
2 – Refrigerator Sensor – Refrigerator sensor connector missing
3 – Refrigerator Defrost Sensor – Refrigerator evaporator internal defrosting sensor connector missing
4 – Refrigerator Fan Error – Refrigerator Fan motor operation failure
5 – Ice Maker Function Error – Ice-ejector and level failed three times or more
6 – CoolSelect Zone Sensor – CoolSelect ZoneTM sensor connector missing
7 – Refrigerator Defrost Error – In the refrigerator room, if frost removal mode is finished due to limited time of 80 minutes error is displayed
8 – Exit Sensor – Air sensor connector missing
9 – Freezer Sensor – Freezer sensor connector missing
10 – Freezer Defrost Error – Freezer evaporator defrosting sensor connector missing
11 – Freezer Fan Error – Freezer Fan motor operation failure
12 – Condenser Fan Error – Condenser Fan motor operation failure
13 – Freezer Defrost Error – In the freezer room, if frost removal mode is finished due to limited time of 70 minutes error is displayed
Samsung RS21HSTPN Side-by-Side Refrigerator 600 Ltrs
Display is 88 88 And Will Not Respond:
To fix this error code, unplug the refrigerator for 1 minute and then plug back in to clear the fault code.
To fix this error code, unplug the refrigerator for 1 minute and then plug back in to clear the fault code.
Error Code 1 E:
Freezer Sensor error.
Freezer Sensor error.
Error Code 2 E:
Freezer Sensor error.
Freezer Sensor error.
Error Code 4 E:
Freezer Defrost Sensor error.
Freezer Defrost Sensor error.
Error Code 5 E:
Fridge Defrost Sensor error.
Fridge Defrost Sensor error.
Error Code 6 E:
Ambient Sensor error.
Ambient Sensor error.
Error Code 8 E or 39 E:
Ice Maker Sensor error.
Ice Maker Sensor error.
Error Code 21 E:
Freezer Fan error.
Freezer Fan error.
Error Code 22 E:
Fridge Fan error.
Fridge Fan error.
Error Code 23 E:
Condenser Fan error.
Condenser Fan error.
Error Code 24 E:
Freezer Defrost error.
Freezer Defrost error.
Error Code 25 E:
Fridge Defrost error.
Fridge Defrost error.
Error Code 26 E or 39 E:
Ice Maker Function error.
Ice Maker Function error.
Error Code 83E, 85E, or 86E Error Codes:
These error codes are related to voltage and current reception at the PBA Inverter. 83E specifically is caused by abnormal current caused by things like a power outage. This error is temporary and can be fixed by unplugging the unit for 1 minute and then plugging it back in.
These error codes are related to voltage and current reception at the PBA Inverter. 83E specifically is caused by abnormal current caused by things like a power outage. This error is temporary and can be fixed by unplugging the unit for 1 minute and then plugging it back in.
Subscribe to: